What was found
DURING LANDING FLARE, FELT CATCH IN ELEVATOR. MAINTENANCE INSPECTED G-WEIGHT DAMPNER IAW 27-31-34, ALL CHECKS GOOD. INSPECTED LT & RT RIGGING AND CABLE CIRCUITS IAW 27-31-00. INSPECTED LAYSHAFT & G-WEIGHT CIRCUIT IAW 27031-00, ALL CHECKS GOOD. PERFORMED RTS OF ELEVATOR AND ELEVATOR TRIM SYSTEM, ALL CHECKS GOOD. SUSPECT DAMPNER MOD, OPS CHECKS GOOD.