SDR MALA090044

Service difficulty report · Strut · Cndair CL6002B19

Difficulty date
March 28, 2009
Submitted
April 1, 2009
Operation
Air carrier
Aircraft
N831AY
Make and model
Cndair CL6002B19
Aircraft serial
8031
Aircraft time
6,262 hours, 5,431 cycles
Part
Strut
Condition
Defective
Location
Nlg
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RECEIVED GEAR DISAGREE WARNING MSG WHEN GEAR LEVER WAS SELECTED UP AFTER T/O. NOSE GEAR FAILED TO RETRACT ACCORDING TO GEAR DISPLAY ON EICAS FOLLOWED ABNORM PROCEED PER CRJ 200 POM UNABLE TO STOW LDG MANUAL RELEASE HANDLE DEFERRED LANDING GEAR RETRACTION SYSTEM PER MEL 32-30-1. MX PROCEDURES C/W, ENTERED IN MM02 MXC NOTIFIED 19398. FOUND NLG SHOCK STRUT SLOW TO EXTEND ON WO SERVICED STRUT IAW 12-12-32, ACCOMPLISHED GEAR EXTENSION CHECKS PART 1+2 OF 32-30-00, CHECKS NORMAL REMOVED FROM MM02 MXC NOTIFIED 19398.