What was found
AFTER DEPARTURE, TAILPIPE HOT FOR RT NR2 ENG ON TAKEOFF ILLUMINATED. PERFORMED EMERGENCY ACTION CARD-NO CHANGE. FOLLOWED EMERGENCY PROCEDURES AND SHUTDOWN ENG, NO TURBULENCE, TRACE ICING IN SNOW. COMPLETED TASK CARD 26-10-302, ALSO OHMED CHECKED DETECTORS- ALL CHECK GOOD. FOUND WIRES WG612 AND W615 CHAFED TOGETHER- REPLACED WIRES WG612 AND WG615. PERFORMED TEST OF FIRE SHORT-CHECKS GOOD. PERFORMED HIGH PWR ENG RUN-OPS CHECK GOOD.