What was found
CMS - FLT 3129 - ON CLIMBOUT, NOSE GEAR CONTINUED TO CYCLE AFTER GEAR RETRACTION. THE CREW PULLED, THEN AFTER 5 MINUTES, RESET THE LANDING GEAR CONTROL CIRCUIT BREAKER. ONCE THE BREAKER WAS RESET, THE GEAR UPLOCKED NORMALLY. THE AIRCRAFT CONTINUED TO MSP. MAINTENANCE ADJUSTED THE RIGGING OF THE UPLIMIT SWITCH. SYSTEM OPERATED SATISFACTORILY DURING A TEST FLIGHT. (X)