What was found
DEPARTING CRW, ON GEAR RETRACTION, RIGHT MAIN GEAR RED UNSAFE LIGHT ILLUMINATED. AIRCRAFT PROCEEDED TO DTW AS AN ALTERNATE. MAINTENANCE PERFORMED OPS CHECK, COULD NOT DUPLICATE. CLEANED AND LUBED UPLOCK ACTUATOR AND ROLLER. ALL CHECKS GOOD.