As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING OVERNIGHT INSPECTION TO COMPLY WITH TC 52-42-51-002 FOUND AFT SERVICE DOOR PNEUMATIC ASSY PRESSURE BELOW SERVICABLE LIMITS. SERVICED DOOR TO 2300 PSI IAW AMM 54-42-51, PROCEDURES A GVI IS REQUIRED AT 24HRS AND 48HRS TO VERIFY THAT THE PNEUMATIC ASSY IS HOLDING TO SERVICABLE LIMITS.