What was found
UPPER CAP OF THE RBL9.00 FLOOR BEAM BETWEEN FS1000.00 - FS1088.20 WAS FOUND TO HAVE CORROSION DAMAGE. PERFORMED PERMANENT REPAIR IAW CRJ 700/900 SRM 53-61-43-001-001-A01, FIGURE 53-61-43-991-801, ITEM 2C, EA 79-2021-212.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPPER CAP OF THE RBL9.00 FLOOR BEAM BETWEEN FS1000.00 - FS1088.20 WAS FOUND TO HAVE CORROSION DAMAGE. PERFORMED PERMANENT REPAIR IAW CRJ 700/900 SRM 53-61-43-001-001-A01, FIGURE 53-61-43-991-801, ITEM 2C, EA 79-2021-212.