What was found
DURING HEAVY CHECK, INSPECTIONS OF THE CFIII, AFT WET AREA, CORROSION ON LT SHEAR PANEL AT FR 87, LBL 13 TO LBL 46 REMOVED BY BLENDING IAW SRM 51-10-03, MAX MATRL REMOVED .002". FOUND TO BE WITHIN LIMITS IAW SRM 53-23-10 AD 03.10X MAG C/OUT, NO FAULT FOUND. BLENDED AREA REPROTECTED IAW SRM 51-23-04, SRM 51=23-05, SRM 51-23-06. REV 45, CORROSION LEVEL 1.