: MAINTEANCE REPORTED BLENDEOUT ON EXTERNAL FUSELAGE SKIN AT STA 1417 STR 29L-32L. THE BLENDOUT EXTENDS INTO FASTENERS AREAS. SRM 53-00-01 FIG 101 ALLOWABLE DAMAGE 1 DOESN'T PROVIDE DAMAGE LIMITS IN CLOSE PROXIMITY TO FASTENERS.