What was found
MAINTEANCE REPORTED BLENDEOUT ON EXTERNAL FUSELAGE SKIN AT STA 1417-1429 STR 32L-34L. THE BLENDOUT EXTENDS INTO FASTENERS AREAS. SRM 53-00-01 FIG 101 ALLOWABLE DAMAGE 1 DOESN'T PROVIDE DAMAGE LIMITS IN CLOSE PROXIMITY TO FASTENERS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAINTEANCE REPORTED BLENDEOUT ON EXTERNAL FUSELAGE SKIN AT STA 1417-1429 STR 32L-34L. THE BLENDOUT EXTENDS INTO FASTENERS AREAS. SRM 53-00-01 FIG 101 ALLOWABLE DAMAGE 1 DOESN'T PROVIDE DAMAGE LIMITS IN CLOSE PROXIMITY TO FASTENERS.