What was found
CRACK INDICATION USING EDDY CURRENT ON ANGLE ON AFT SIDE OR FRAME AT STATION 544 LONGERON 10 LEFT. CRACKED IN TWO PLACES AROUND RIVETS -- REMOVED AND INSTALLED NEW CLIP.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK INDICATION USING EDDY CURRENT ON ANGLE ON AFT SIDE OR FRAME AT STATION 544 LONGERON 10 LEFT. CRACKED IN TWO PLACES AROUND RIVETS -- REMOVED AND INSTALLED NEW CLIP.