What was found
AT STATION 484 LONGERON 19 RIGHT HAS A DENT BEYOND LIMITS PER SRM 53-04. FABRICATED AND INSTALLED DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT STATION 484 LONGERON 19 RIGHT HAS A DENT BEYOND LIMITS PER SRM 53-04. FABRICATED AND INSTALLED DOUBLER.