As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING GEAR FREE-FALL DEMO THE MANUAL GEAR EXTENSION LEVER WOULD ONLY EXTEND 3 INCHES, NOT ENOUGH TO EXTEND GEAR. MAINTENANCE FOUND CABLE 112A RUNNING ON OUTSIDE OF 3 CABLE SECTOR GUARDS, PLACED CABLE CORRECTLY UNDER SECTOR CABLE GUARDS. INSPECTED CABLE NO DAMAGE NOTED. ALL OPS CHECKS OF SYSTEM WERE GOOD.