As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSP OF AFT CARGO DOOR, A 2 INCH CRACK WAS FOUND IN THE OUTER PAN RADIUS IN THE UPPER FWD CORNER OF THE AFT DOOR. THE CRACK WAS STOP DRILLED, AND AN EXTERNAL DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 52-03 FIG 8. AREA WAS TREATED IAW SRM 51-10-3. OPERATIONAL CHECK AND PRESSURE CHECK GOOD. A/C RETURNED TO SERVICE.