What was found
ETOPS SIGNIFICANT SYSTEM: APU FAULT ON 2 START ATTEMPTS MAINT LIGHT ALSO. T/S APU FAULT IAW FIM 49-60 TASK 801 FOUND STARTER/GENERATOR AT FAULT. REMOVED AND REPLACED APU STARTER GENERATOR IAW B737-800 M/M 49-41-21 OPS CHECK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS SIGNIFICANT SYSTEM: APU FAULT ON 2 START ATTEMPTS MAINT LIGHT ALSO. T/S APU FAULT IAW FIM 49-60 TASK 801 FOUND STARTER/GENERATOR AT FAULT. REMOVED AND REPLACED APU STARTER GENERATOR IAW B737-800 M/M 49-41-21 OPS CHECK NORMAL.