Service difficulty report · Converter · Gulstm GIVXG450

Difficulty date
August 14, 2011
Submitted
December 30, 2011
Operation
Air carrier
Aircraft
N452NS
Make and model
Gulstm GIVXG450
Aircraft serial
4094
Part
Converter
Part number
100201022052
Part serial
HT001333
Condition
Failed
Location
Internal
Part time
2,640 hours
Stage of operation
IN
How discovered
O
Nature of condition
H, J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING PRE-FLIGHT, CAPTAIN NOTICED 2 MOMENTARY CAS MESSAGES PRIOR TO THE APU GENERATOR AUTO-SWITCHING TO OFFLINE, AND DU2 LOSING POWER. THE CAS MESSAGES DISPLAYED WERE THE AMBER "APU GENERATOR OVERLOAD", AND THE BLUE, "R 60 HZ POWER FAIL". THE 60 HZ CONVERTER IN THE AFT EQUIPMENT BAY WAS CHECKED AND FOUND A STRONG ODOR. THE INVERTER WAS FOUND TO HAVE HOLES BURNED THROUGH THE METAL FRAME OF THE INVERTER. THE ACFT WAS MEL`D WITH 24-15.