What was found
PERFORMED PITOT LINE P1 CONTAMINATION REMOVAL IAW CRJ 550 AMM 34-11-00-100-801. NO CONTAMINATION NOTED. PERFORMED PITOT LINE P2 CONTAMINATION REMOVAL IAW CRJ 550 AMM 34-11-00-100-802. APPROXIMATELY 5ML OF WATER PURGED. PERFORM PITOT STATIC P3 CONTAMINATION REMOVAL IN ACCORDANCE WITH CRJ 550AMM 34-11-00-100-803. NO CONTAMINATION NOTED. PERFORMED STATIC LINE PITOT S1/ COPILOT S2 CONTAMINATION REMOVAL IN ACCORDANCE WITH CRJ 550 AMM 34-11-00-100-804. NO CONTAMINATION NOTED PERFORMED STATIC LINE. CONTINUED NEXT BLOCK. COPILOT S1 PILOT S2 CONTAMINATION REMOVAL IN ACCORDANCE WITH CRJ 550AMM 34-11-00-100-805 NO CONTAMINATION NOTED. PERFORMED STATIC LINE S3 CONTAMINATION REMOVAL IN ACCORDANCE WITH CRJ 550AMM 34-11-00-100-806. NO CONTAMINATION NOTED. PERFORM PITOT STATIC SYSTEM LEAK TEST NO DEFECTS NOTED AT THIS TIME.