What was found
ELONGATED HOLES ON FLOOR SILL AT STRINGER 17R AND FS939.00 - FS953.00. REPAIRED ELONGATED HOLES ON FLOOR SILL AT STRINGER 17R AND FS939.00 - FS953.00 IAW EA 109-2025-031.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ELONGATED HOLES ON FLOOR SILL AT STRINGER 17R AND FS939.00 - FS953.00. REPAIRED ELONGATED HOLES ON FLOOR SILL AT STRINGER 17R AND FS939.00 - FS953.00 IAW EA 109-2025-031.