What was found
DURING ENGINE RUN OPERATIONAL CHECK FOR IDG REPLACEMENT, NO GENERATOR OUTPUT. REPLACED IDG DUE TO SHEARED SHAFT IAW AMM 24-11-01, OP AND LEAK CHECK IAW 71-00-00, NO LEAK NOTED AND OP CHECK GOOD. ETOP SS'S
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ENGINE RUN OPERATIONAL CHECK FOR IDG REPLACEMENT, NO GENERATOR OUTPUT. REPLACED IDG DUE TO SHEARED SHAFT IAW AMM 24-11-01, OP AND LEAK CHECK IAW 71-00-00, NO LEAK NOTED AND OP CHECK GOOD. ETOP SS'S