SDR NOCA00111

Service difficulty report · Relay · Boeing 75728A

Difficulty date
January 5, 2011
Submitted
January 5, 2011
Operation
Air carrier
Aircraft
N755NA
Make and model
Boeing 75728A
Aircraft serial
30043
Part
Relay
Part number
KDAE4F
Condition
Failed
Location
Equipment Fan
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIR TURNBACK , EICAS MESSAGE EQUIPMENT OVERHEAT DISPLAYED OVHT LGT ILLUMINATED, EICAS MESSAGE EQUIPMENT CLG FAN DISPLAYED. OVERHEAT LIGHT REMAINED ILLUMINATED WHEN ALTERNATE WAS SELECTED. EQUIPMENT CLG FLOW DISPLAYED ON GROUND. CIRCUIT BREAKERS FOR AFT EQUIP EXHAUST FANS 1 AND 2 OPEN AT P37 AND P70 PANELS. EXHAUST FAN 1 FAILED TO RESET. EXHAUST FAN 2 RESET SUCCESSFULLY OPS CHECKED NORMAL. REPLACED EQUIPMENT VENT FAN RELAY K346 PER WDM 21-58-21, OPS CHECKED GOOD.