What was found
RIGHT ENG FIRE LP 1 STATUS MSG. CLEANED WAFER CONNECTORS AT M683 RIGHT ENGINE FIRE DETECTION CARD, T/S PER FIM 26-11-00 FIG 104 ALL LOOPS RESISTANCE & INSULATION CHECKS WITH IN LIMITS SYSTEM, OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT ENG FIRE LP 1 STATUS MSG. CLEANED WAFER CONNECTORS AT M683 RIGHT ENGINE FIRE DETECTION CARD, T/S PER FIM 26-11-00 FIG 104 ALL LOOPS RESISTANCE & INSULATION CHECKS WITH IN LIMITS SYSTEM, OK FOR SERVICE.