What was found
EMERGENCY LANDING AT CHS DUE TO LEFT BUS OFF, L BUS TIE ISLN AND L/R UTILITY BUS OFF EICAS MESSAGES. THEN GOT L GEN CONT EICAS. GCU AND BPCU REPLACED AFTER FIM USED FOR T/S. L GEN TRIPPED FAULT REPEATED T/S PER FIM AND REPLACED THE LT IDG. FURTHER T/S FOUND 1.1 MEGA OHMS BETWEEN D2108EA13 AND D13. FOUND CONNECTOR D1014P AND BACKSHELL DAMAGED. REPLACED D1014P AND REPINNED BROKEN WIRE AT PIN 12, OPERATION CHECK NORMAL.