What was found
JUST PRIOR TO LEVEL OFF AFTER TAKE OFF THE FLIGHT ATTENDANT AT DOOR 4R CALLED TO REPORT SHE SMELLED ELECTRICAL SMOKE AND IT WAS HAZY. RECEIVED "COND R CAB VENT FAULT" FOLLOWED COM AND SHUT OFF CABIN FANS AND THE SMELL AND HAZE DISSIPATED AND LANDING WAS UNEVENTFUL. FOUND RECIRCULATION FAN RT (210HG) FAULT AND FAN FROZEN.