What was found
FWD CARGO COMPARTMENT STA 920 FLOORBEAM WEB VERTICAL SUPPORT FOUND 3 RIVETS SHEARED. REPLACED RIVETS AS PER SRM 51-30-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO COMPARTMENT STA 920 FLOORBEAM WEB VERTICAL SUPPORT FOUND 3 RIVETS SHEARED. REPLACED RIVETS AS PER SRM 51-30-03.