What was found
FOUR RIVETS FOUND NOT INSTALLED AT FWD CARGO COMPT STA 960 FLOORBEAM UPPER CHORD, BL 0 AND BL 6. INSTALLED RIVETS AS PER SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUR RIVETS FOUND NOT INSTALLED AT FWD CARGO COMPT STA 960 FLOORBEAM UPPER CHORD, BL 0 AND BL 6. INSTALLED RIVETS AS PER SRM 51-30-02.