Service difficulty report · Indicator · Dhav DHC8102

Difficulty date
October 18, 1998
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N816EX
Make and model
Dhav DHC8102
Aircraft serial
329
Part
Indicator
Part number
68001008010
Condition
Failed
Location
Cockpit
Stage of operation
NR
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EN ROUTE TO PIT, THE MAIN AND AUXILIARY BATTERY CAUTION LIGHTS ILLUMINATED. THE TEMPERATURE MONITOR WENT DEAD ASSOCIATED WITH THE CIRCUIT BREAKER POPPING. THE CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT SYSTEM, FOUND THE TEMPERATURE MONITOR AT FAULT. THE MONITOR WAS REMOVED AND REPLACED IAW DHC PROCEDURES. TESTED OK. A/C RETURNED TO SERVICE. (M)