What was found
CLIMBED TO CRUISE, CREW REPORTED NR 3 GEN BREAKER LIGHT CAME ON & WOULD NOT HOLD POWER, NR 2 GEN BREAKER & FIELD LIGHTS CAME ON, NO FAULT NOTED, RESET NR 2 GEN & 20 MIN LATER FAULT RETURNED NO LIGHTS. DID NOT RESET NR 2 BREAKER. DIVERTED ACFT, & LANDED WITHOUT INCIDENT. MX INSP & T/SHOT ACFT GEN SYS, MX FOUND NR 3 GEN CONTROL PANEL NOT SECURED, MX SECURED NR 3 GCU IAW MM & PERFORMED AN OPS CHK IAW MM, OPS CHK ON GROUND FOUND NORMAL. OPS CHK OF NR 2 GEN AC POWER PERFORMED IAW 24-22-00, OPS NORMAL. BUSS PROTECTION PANEL R & R IAW MM; GCU NR 2 SWAPPED TO APU GCU FOR T/SHOOTING. NR 2 AC POWER GEN SYS & APU GEN SYS OPS TESTED & CHKD NORMAL IAW MM. FERRY FLT BACK TO MIA FOR FURTHER INSP. ACFT RETURNED W/OUT INCIDENT.