As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INCOMING INSPECTION AT GE WALES, DEFECTS ON THE INTERSTAGE SEAL HAVE BEEN NOTED. THE INTERSTAGE SEAL HAS 6 DENTS TO 5 CROSSOVER PAD HOLE EDGES. DR # 02214321 WAS REJECTED BY THE OEM AS THE CONDITION COULD NOT BE SUBSTANTIATED. PLEASE NOTE, THE PART WILL NEVER BE SALVAGEABLE. TO BE REPORTED I.A.W AMC-20 9.3 (J) ANY DEFECT IN A LIFE-CONTROLLED CRITICAL PART THAT CAUSES ITS RETIREMENT BEFORE THE COMPLETION OF ITS FULL SERVICE LIFE.