Service difficulty report · Battery · Snias AS350B3

Difficulty date
July 26, 2014
Submitted
July 28, 2014
Operation
Air carrier
Aircraft
N4204
Make and model
Snias AS350B3
Aircraft serial
4204
Aircraft time
3,248 hours, 9,892 cycles
Engine
Tmeca ARRIEL2B
Engine time
3,248 hours, 7,648 cycles
Part
Battery
Part number
RG350
Part serial
40542995
Condition
Unserviceable
Location
Main
Part time
226 hours
Stage of operation
AA
How discovered
O
Nature of condition
G, B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THE RADIOS & VEMD WENT OFF LINE & HE COULD SMELL SMOKE. REMOVED INSTRUMENT PANEL HOOD & INSPECTED THE WIRING FOR THE RADIOS & VEMD FOUND NO DISCREPANCIES. REMOVED THE 30 ALPHA PANEL & INSPECTED WIRING NO DISCREPANCIES. INSPECTED 31 ALPHA PANEL WHICH HOUSES THE CB`S OF THE EQUIP THAT WENT OFF LINE. PP5 & PP6 ARE THE BUSS BARS THAT FEED POWER TO THESE CB`S & FOUND NO DISCREPANCIES. GAINED ACCESS TO THE MASTER ELEC BOX IN THE AFT BAGGAGE COMPARTMENT & INSPECTED ALL COMPONENTS AS WELL AS CHECKING THE FUSES TO PP5 & PP6. ALL LOOKED NORMAL. INSPECTED THE ARMATURE & BRUSHES OF THE STARTER GEN & ALL LOOKED NORMAL. APPLIED POWER TO THE ACFT & CHECKED THE VOLTAGE AT PP6 & WAS ONLY GETTING 8 VDC THEN CHECKED VOLTAGE AT THE FUSE IN THE MASTER ELEC BOX & WAS ONLY GETTING 11 VDC. DETERMINED THAT A FAULTY BATTERY WITH LOW VOLTAGE IS THE CAUSE FOR THE RADIOS & VEMD GOING OFF LINE. THE FUEL BOOST WAS NOT FUNCTIONING WHICH IS SUPPLIED POWER FROM PP6. THE BATTERY WAS REPLACED & ALL THE RADIOS, VEMD & FUEL BOOST PUMP WERE OPERATIONAL. THE VEMD SELF-TESTED NORMAL WITH NO GOV LIGHT ILLUMINATING. A GND RUN WAS PERFORMED WITH ALL SYS OPERATING NORMAL. THE STARTER GEN WAS SUPPLYING THE PROPER VOLTAGE TO THE SYS. IN CONCLUSION I COULD ONLY DETERMINE THAT THE SMELL EXPERIENCED BY THE CREW WAS A HOT SMELL COMING FROM THE VEMD WHICH HAD NO COOLING AT THE TIME.