As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AIRCRAFT SUB FLOOR HAS MULTIPLE DENTS AND CRUSHED HONEYCOMB CORE. THIS AIRCRAFT WAS ALTERED WITH THE EMS KIT NUMBER 135M-100. THE CAUSE OF THE DAMAGE IS SUSPECTED DUE TO THE INSTALLED MEDICAL FLOOR PALATE P/N EC135M-2000-1 IS INADEQUATE TO SUPPORT THE STRETCHER ASSEMBLY WHEN LOADED WITH A PATIENT AND THE FRONT WHEELS OF THE STRETCHER ARE CRUSHING THE FLOOR. AWAITING A REPAIR FROM MANUFACTURING ENGINEERING.