What was found
FLT 2 PRECAUTIONARY LANDING DURING FLIGHT , BATTERY DISCHARGE CAUTION ILLUMINATED, CHECKED INSTRUMENTS, 1 AT 85 AMPS; GEN 2 AT -0.5 AMPS, PERFORMED EP FOR GEN 2 FAILURE. DURING TROUBLESHOOTING, FOUND #2 STARTER GENERATOR FAILS TO TURN DURING START UP. REMOVED AND REPLACED STARTER GENERATOR IAW AMM 24-30-00, 4-2. MOC COMPLETED IAW AMM 05-60-00, 6-12.