What was found
DURING RUN-UP, OVERSPEED FAIL ON CAD # 1 (SENSOR TEST OUT OF LIMIT ON PINS 4-5, READS 222-224.5). REPLACED MAGNETIC SENSOR (ARRIEL SPC: 77-14-00-01-020C) IAW 77-14-00-900-802-A01 MOC OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING RUN-UP, OVERSPEED FAIL ON CAD # 1 (SENSOR TEST OUT OF LIMIT ON PINS 4-5, READS 222-224.5). REPLACED MAGNETIC SENSOR (ARRIEL SPC: 77-14-00-01-020C) IAW 77-14-00-900-802-A01 MOC OK.