What was found
DURING HOVER, RIGHT SIDE ONLY MASTER CAUTION ILLUMINATED. #2 HYD PUMP INDICATED A FLUCTUATION IN PRESSURE FROM 110 TO 30. REMOVED AND REPLACED PRESSURE SWITCH/TRANSDUCER; MOC COMPLETED IAW AMM 29-39-00, 8-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HOVER, RIGHT SIDE ONLY MASTER CAUTION ILLUMINATED. #2 HYD PUMP INDICATED A FLUCTUATION IN PRESSURE FROM 110 TO 30. REMOVED AND REPLACED PRESSURE SWITCH/TRANSDUCER; MOC COMPLETED IAW AMM 29-39-00, 8-1.