Service difficulty report · O2 Mask · Fokker F28MK4000

Difficulty date
January 11, 2000
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N492US
Make and model
Fokker F28MK4000
Aircraft serial
11159
Part
O2 Mask
Condition
Failed Deploy
Location
Cabin
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BOI - DURING CLIMB-OUT AND AFTER TURNING ON AIRFOIL ANTI-ICE, CREW NOTICED AIR FOIL VALVES CLOSED AT 10000 FEET, CREW NOTED PRESSURE DIFFERENTIAL BETWEEN 2 AND 3 PSI. CREW DECIDED TO RETURN TO BOISE.. ALL PASSENGER OXYGEN MASKED AUTOMATICALLY DEPLOYED. ONE FLIGHT ATTENDENT OXYGEN MASK FAILED TO DEPLOY IN THE AFT STATION. REPOSITIONED SPRING ON OXYGEN MASK DOOR. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.

More about the Fokker F.28 MK4000