YYC- CABIN FLOOR STRUCTURE AT FRAME 3450 TO 4175 FLOORBEAM BL 1127 RT HAS A CRACKED AND CORRODED SPOT. REPAIRED IAW FOKKER SRM 53-11-05 FIGURE 3, 51-31-01 AND 53-02-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
YYC- CABIN FLOOR STRUCTURE AT FRAME 3450 TO 4175 FLOORBEAM BL 1127 RT HAS A CRACKED AND CORRODED SPOT. REPAIRED IAW FOKKER SRM 53-11-05 FIGURE 3, 51-31-01 AND 53-02-14.