What was found
PDX- CORROSION AT CAMLOCK RECEPTICLE BELOW CABIN FLOOR SUPPORT AT STATION 4425, LBL 24, WL 22.5. REPAIRED IAW FOKKER SRM 51-31-01, PAGE 13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PDX- CORROSION AT CAMLOCK RECEPTICLE BELOW CABIN FLOOR SUPPORT AT STATION 4425, LBL 24, WL 22.5. REPAIRED IAW FOKKER SRM 51-31-01, PAGE 13.