What was found
AFTER TAKEOFF, NR 2 STANDBY PUMP HOT LIGHT BEGAN CYCLING AND THEN CAME ON STEADY. PERFORMED NR 2 STANDBY PUMP HOT CHECKLIST AND LIGHT EXTINGUISHED APPROX A MINUTE. OPERATED NORMALLY FOR REMAINDER OF FLIGHT. MX CLEANED CONNECTOR ON NR 2 STANDBY PUMP. GROUND RAN ACFT AND CYCLED APPLICABLE HYDRAULIC SYSTEM USING NR 2 STANDBY PUMP. LIGHT REMAINED EXTINGUISHED. NO FURTHER DEFECTS NOTED. NO PARTS REPLACED. ACFT RETURNED TO SERVICE.