Service difficulty report · Controller · Cndair CL6002C10

Difficulty date
October 9, 2005
Submitted
October 13, 2005
Operation
Air carrier
Aircraft
N603QX
Make and model
Cndair CL6002C10
Aircraft serial
10011
Aircraft time
10,569 hours, 7,873 cycles
Part
Controller
Part number
165911
Part serial
2994
Condition
Malfunctioned
Location
Window Heat
Part time
6,917 hours, 5,143 cycles
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT WINDOW HEAT CAUTION MESSAGE. CYCLED PER CHECKLIST, CAUTION WENT OFF. AFTER 10 MIN MESSAGE CAME BACK. F/O WINDOW FEELS COLD. MX PLACED ON MEL 30-41-1(A), RSI 352674. C/W STEP 1 OF EA R-56-17 BY CHANGING ELEMENT TO SPARE. PERFORMED OPS CHECK OF WINDOW, STILL COLD, MEL CONTINUED. PERFORMED RESISTANCE CHECK OF ALL 3 SENSING ELEMENTS AND HEATER ON RT WINDSHIELD. NO DEFECTS NOTED. PERFORMED RESISTANCE AND MEGGER CHECKS OF RT WINDSHIELD WIRES, NO DEFECTS NOTED. REPLACED RT WINDSHIELD TEMPERATURE CONTROLLER IAW TASK 30-41-06-000-801-A01 & 30-41-06-400-801-A01 AS A PRECAUTION. OPERATIONAL CHECKS GOOD. MEL CLEARED AND WIRES RECONNECTED TO PRIMARY ELEMENT. AIRCRAFT RETURNED TO SERVICE.