Service difficulty report · Sensor · Cndair CL6002C10

Difficulty date
March 25, 2006
Submitted
March 31, 2006
Operation
Air carrier
Aircraft
N607QX
Make and model
Cndair CL6002C10
Aircraft serial
10024
Aircraft time
11,969 hours, 8,819 cycles
Part
Sensor
Condition
Malfunctioned
Location
Windshield Heat
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PDX- FLIGHT 2468 LEFT WINDSHIELD CAUTION IN FLIGHT AFTER COMPLETING THE CHECKING RESET PROCEDURE THE CAUTION EXTINGUSHED THE WINDISHELD REMAINED COLD TO THE TOUCH. INSPECTED AND FOUND LOOSE WIRE AT PRIMARY TEMP SENSOR ON CAPT'S WINDSHIELD TERMINAL BLOCK. TIGHTENED LOOSE WIRE CONNECTION AND COMPLIED WITH WINSHIELD/SIDE WINDOW TEMPERATURE CONTROLLER. ADJUSTMENT/TEST OPS CHECKS GOOD. NO PARTS REPLACED. AIRCRAFT RETURNED TO SERVICE.