As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GEG - NR 2 AC GEN CAUTION ILLUMINATED. GENERATOR CAUTION WENT OUT WHEN RESET PER CHECKLIST. NO ELECTRICAL SYSTEM CONFIGURATION CHANGES WHAT SO EVER PRECEDED THE EVENT. DIVERTED TO GEG. LANDING UNEVENTFUL. INSPECTED CONNECTOR 9811P722 WITH NO DEFECTS FOUND. PERFORMED OPERATIONAL TEST OF GENERATOR IAW 24-21-00-710-801. CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE. NO PARTS REPLACED.