What was found
C-CHECK - CORROSION ON THE ATTACH FLANGE OF FRAME FS 629.00 BETWEEN STR 27 AND 26R. BLENDED CORROSION IAW SRM 51-21-06-001-001-A01. REMOVED .003", REMAINING MATERIAL THICKNESS IS .060" AND WITHIN LIMITS OR SRM 53-31-06-101-003-A01. ALODINED IAW 51-21-11-001-001-A01. PRIMED IAW SRM 51-21-11-001-001-A01. PAINTED AREA IAW SRM 51-25-16-001-001-A01. APPLIED AV8 CORROSION PREVENTATIVE COMPOUND IAW SRM 51-21-11-001-001-A01.