What was found
C CHECK -LT AND RT SIDE OF 280 BEAM SHOWS SIGNS OF CORROSION. BLENDED CORROSION RT 280 BEAM IAW SRM 51-11-00-001-001-A01. FOUND BEAM TO BE CRACKED. REMOVED BEAM IAW SRM 51-42-06-001-001-A01 AND 51-42-13-001-001-A01. CUT NEW 280 BEAM. PERFORMED LPI ON CUTLINE, NO CRACKS NOTED IAW NDTM LPI 51-20-008-230-A01. LOCATED, DRILLED AND DEBURRED ALL HOLES IN THE NEW BEAM IAW SRM 51-40-11-001-001-A01. INSTALLED 280 BEAM IAW SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01 AND 51-42-21-001-001-A01. TREATED, PRIMED IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01 AND 51-25-06-001-001-A01. COMPLETED BEAM INSTALLATION IAW REO 670-53-11-047. PRIMED & TOP-COATED IAW SRM51-25-06-001-001-A01. APPLIED CORROSION PREVENTATIVE COMPOUND IAW SRM51-21-11-001-001-A01.