What was found
C-CHECK DURING INSP FOUND CORRODED ON FS 280 JOINT STRAP AT STRINGER 27RBL 3". REMOVED 2 RIVETS AND BLENDED CORROSION IAW SRM 51-21-06-001-001-A01. BLENDED AREA IS A NO-DAMAGE ALLOWED AREA IAW SRM 53-21-01-101-002-A01. PERFORMED ECI ON BLENDED AREA . NO CORROSION OR CRACKS FOUND IAW NDTM ECI 51-20-006. SENT FOR ENGINEERING. RECEIVED ENGINEERING. BLEND IS W/IN LIMITS OF REO 670-53-21-559. ALLODINED IAW SRM 51-21-11-001-001-A01. PRIMED AREA IAW CRJ700 51-21-06-001-001-A01. INSTALLED RIVETS IAW SRM 51-42-06-001-001-A01. PAINTED IAW SRM 51-25-16-001-001. APPLIED CORROSION INHIBITING COMPOUND IAW SRM 51-21-11-001-001-A01. ALL WORKS IS IN CONFORMITY WITH REO 670-53-21-559/3.