What was found
C CHECK -THERE IS AN APPROX 6" CHAFED AREA ON THE BOTTOM OF THE MAIN HINGE ARM FOR THE AFT SERVICE DOOR. REMOVED CHAFE DAMAGE BY BLENDING IAW SRM 51-14-00-02-01. DIMENSIONS OF BLEND ARE AS FOLLOWS: LENGTH 1.20", WIDTH 0.38" AND DEPTH OF BLEND IS .004". BLENDED REMAINING CHAFE DAMAGE TO A SMOOTH CONTOUR TO REMOVE DAMAGE AND MAPPED AREA FOR ENGINEERING. HFEC IAW -8 NDTM PART 6, 51-00-01 AT BLENDED AREA, NO CRACKS NOTED. COMPLETED THE REPAIR ON THE BOTTOM OF MAIN HINGE ARM REF T/C RD 8/4-52-579 STEPS 3 AND 4.