What was found
C CHECK - CORROSION ON STRINGER 26R AT FS340. REMOVED CORROSION, BLENDS FOUND TO BE OUT OF LIMITS IAW SRM 53-21-03-101-006-A01. REMOVED STRINGER 26R IAW SRM 51-42-06-001-001-A01. LOCATED FASTENER HOLES ON NEW STRINGER IAW SRM 51-40-11-001-001-A01. INSTALLED NEW STRINGER IAW SRM 51-42-06-001-001-A01. APPLIED TOPCOAT IAW SRM 51-25-16-001-001-A01. APPLIED CORROSION INHIBITING COMPOUND TO AFFECTED AREAS IAW SRM 51-21-11-001-001-A01. ALL WORK DONE IN CONFORMITY OF REO 670-53-21-584.