What was found
C-CHECK - COCKPIT FLOOR SUPPORT ANGLE ON FWD SIDE OF FS 280 BEAM SHOWS SIGNS OF CORROSION. REMOVED CORRODED FLOOR SUPPORT ANGLE FOR ACCESS IAW SRM 51-42-06-001-001-A01. BLENDED CORROSION IAW SRM 51-21-06-001-001-A01. ORIGINAL THICKNESS IS .063". BLENDED .015" MATERIAL FROM ANGLE MAXIMUM BLEND ALLOWED IS .048". FOUND BLEND TO BE OUT OF LIMITS IAW SRM 53-21-43-101-001-A01. LOCATED NEW FASTENER HOLES IN NEW ANGLE IAW SRM 51-40-11-001-001-A01. INSTALLED ANGLE IAW SRM 51-42-21-001-001-A01 AND 51-23-02-001-001-A01. TOPCOATED AND APPLIED CORROSION INHIBITING COMPOUND IAW SRM 51-25-16-001-001-A01 AND 51-21-11-001-001-A01.