What was found
LT GREEN MAIN GEAR INDICATION LIGHT FAILS TO ILLUMINATE INTERMITTENTLY. LIGHT ILLUMINATED WHEN LENS IS PUSHED IN. LANDED WITHOUT INCIDENT. R & R LANDING GEAR CONTROL PANEL IAW AMM TASK 32-31-01-000-801 AND TASK 32-31-01-400-801. LMG GREEN INDICATION LIGHT CHECK GOOD. FUNCTIONAL TEST OF LGCIP FAIL AT STEP 4A(9). R & R PSEU IAW AMM 32-61-01-000-801 AND TASK 32-61-01-400-801. PSEU OPS CHECK GOOD . DID NOT FIX ORIGINAL DISCREPANCY. FOUND NOSE GEAR NOT CENTERED, CENTERED NOSE GEAR AND COMPLIED WITH FUNCTIONAL TEST OF LGCIP IAW AMM TASK 32-31-01-000-801 AND TASK 32-31-01-400-801. FUNTIONAL TEST GOOD NO DEFECTS NOTED. RETURNED TO SERVICE.