Service difficulty report · Controller · Cndair CL6002C10

Difficulty date
January 20, 2011
Submitted
January 24, 2011
Operation
Air carrier
Aircraft
N617QX
Make and model
Cndair CL6002C10
Aircraft serial
10130
Aircraft time
19,433 hours, 14,255 cycles
Part
Controller
Part number
47388904
Part serial
1030
Condition
Malfunctioned
Location
Zone 200
Part time
18,938 hours, 13,895 cycles
Stage of operation
UK
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FIRE SYST FAULT STATUS MESSAGE. PLACED ON MEL 26-00-1. CLEARED 1/21 BY: INTERROGATED MDC, FOUND LT ENG LOOP B FAILED OPEN AND LT ENG LOOP B FAILED SHORT ALONG WITH NUMEROUS ENG/CARGO SQUIB AND BOTTLE FAILED MSGS IN FAULT HISTORY ON 1/20/11. NO OTHER ASSOCIATED HISTORY. PERFORMED RESISTANCE CHECK OF LT AND RT ENG LOOP B IAW WM 71-50-01 AND 26-11-01. NO DEFECTS NOTED. BOTHER ENG LOOPS READ 27-29 OHMS. PERFORMED VISUAL INSP OF LT ENG FIRE LOOPS. NO DEFECTS NOTED. REMOVED FIDEEX IAW AMM TASK 26-10-01-000-801 AND REPLACED W/ SERVICABLE FIDEEX IAW AMM TASK 26-10-01-400-801 AS A PRECAUTIONARY MEASURE. OPS CHECK GOOD. FIDEEX PLACED IN QUARANTINE PROGRAM. CLEAR MEL. RETURNED TO SERVICE.