What was found
RECEIVED WINDSHEILD CONTROL CAUTION, FO'S WINDSHEILD FOGGED UP. DIVERTED AND ACCOMPLISHED UNEVENTFUL LANDING. COMPLIED WITH FIM TASK 30-40-00-810-805 FOR WINDSHIELD CTRL CAUTION. NO FAULTS FOUND. CHECK WIRE CONNECTIONS AT FO'S WINDSHIELD AND FOUND NO DEFECTS. CHECK ELECTRICAL RESISTANCE OF FO'S WINDSHIELD IAW AMM TASK 30-41-00-760-801, NO DEFECTS FOUND. R & R NR 2 ANTI-ICE CONTROLLER WITH C/P 3041-P2 CONNECTED IAW AMM TASK 30-41-01-00-801 & 30-41-01-400-801 FOR PRECAUTIONARY MEASURE. OPS CHECK GOOD IAW AMM TASK 30-41-00-710-802. RETURNED TO SERVICE.