What was found
LEFT HORIZONTAL STAB FWD SPAR WEB SMOKING RIVETS AND FRETTING INDICATIONS FROM L MAIN ATTACH FITTING OBD APPROX 9 INCHES. REMOVED DAMAGED FASTENERS AS NECESSARY IAW SRM 51-42-45-02-01. BRENDED OUT FETTING DAMAGED FASTENERS AS NECESSARY IAW SRM 51-14-00-02-03. MIN REMAINING THICKNESS .061" REF NTM 51-00-04-910-801 PT 1. CONFIRMED BLENDED AREA CRACK FREE USING HFEC REF NDTM 51-00-06-910-801 PT 1. FOUND BLENDS IN LIMITS IAW RD 8/4-55-800. ALODINED AND PRIMED IAW RD 8/4-55-800. INSTALLED MISSING FASTENERS IAW SRM 51-42-45-02-01.